Radiation Dose In Paediatric Patients Using Geant4

Authors

  • Siti Amira Othman UTHM
  • Lee Yan Lin UTHM

Keywords:

Paediatric Patients, Monte Carlo Simulations, Geant4, Paediatric Dosimetry, Radiation Protection

Abstract

Paediatric patients are more sensitive to ionizing radiation than adults due to their developing organs and longer expected lifetime. Therefore, accurate assessment of radiation dose during computed tomography (CT) examinations is essential for optimizing diagnostic imaging protocols. This study investigates the application of the Geant4 Monte Carlo simulation toolkit to estimate radiation dose distribution in paediatric patients. A computational anthropomorphic phantom representing a five-year-old child was developed to simulate photon interactions within different organs and tissues. X-ray energy spectra corresponding to tube voltages of 80, 100 and 120 kVp were considered to investigate their influence on absorbed dose. Organ-specific energy deposition was evaluated for radiosensitive organs, including the brain, thyroid, lungs, liver and gonads. The proposed simulation framework provides an opportunity to identify dose variations across organs and evaluate optimized imaging parameters. This approach supports improved paediatric radiation protection and dose optimization.

References

Agostinelli, S., et al. (2003). Geant4—A simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A, 506(3), 250–303. https://doi.org/10.1016/S0168-9002(03)01368-8

Allison, J., et al. (2006). Geant4 developments and applications. IEEE Transactions on Nuclear Science, 53(1), 270–278. https://doi.org/10.1109/TNS.2006.869826

Allison, J., et al. (2016). Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A, 835, 186–225. https://doi.org/10.1016/j.nima.2016.06.125

Attalla, E. M., El Gendy, R. A., Abdelbadee, S. A., Mosallam, A. S., et al. (2026). Assessment of radiation doses in computed tomography scans using simulation models versus experimental verification and cancer risk estimation in pediatric phantom. Egyptian Journal of Radiology and Nuclear Medicine, 57, Article 55. https://doi.org/10.1186/s43055-026-01715-1

Carver, D. E., Kost, S. D., Fernald, M. J., Lewis, K. G., Fraser, N. D., Pickens, D. R., Price, R. R., & Stabin, M. G. (2015). Development and validation of a GEANT4 radiation transport code for CT dosimetry. Health Physics, 108(4), 419–428. https://doi.org/10.1097/HP.0000000000000243

International Commission on Radiological Protection. (2007). The 2007 recommendations of the International Commission on Radiological Protection. Annals of the ICRP, 37(2–4), 1–332. https://doi.org/10.1016/j.icrp.2007.10.003

International Commission on Radiological Protection. (2020). Paediatric reference computational phantoms (ICRP Publication 143). Annals of the ICRP, 49(2).

International Commission on Radiological Protection. (2024). Paediatric mesh-type reference computational phantoms (ICRP Publication 156). Annals of the ICRP, 53(1–2). ICRP Publication 156

Lee, C., Kim, K. P., Long, D. J., & Bolch, W. E. (2012). Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation. Medical Physics, 39(4), 2129–2146. https://doi.org/10.1118/1.3693052

Sekkat, H., Khallouqi, A., El Rhazouani, O., & Halimi, A. (2025). Deep learning-based organ dose prediction in pediatric head CT using fully automated tissue segmentation and newly developed voxelized phantoms in GATE/Geant4 simulation toolkit. Radiation Measurements. https://doi.org/10.1016/j.radmeas.2025.107597

Downloads

Published

2026-11-16

Most read articles by the same author(s)